When a hangar foam fire suppression system inadvertently discharges the results can be damaging or even deadly.
Foam type fire suppression system.
Foam concentrate water and air.
The surfactants used must produce foam in concentration of less than 1.
If fire protection option 1 is used a foam water deluge system in hangars housing aircraft with a wingspan area of greater than 3 000 square feet supplemental protection is also required.
Every facility has different needs when it comes to fire suppression.
Medium and high expansion where the expansion ratios are greater from 20 to 1 up to 1 000 to 1.
One example is the ansul foam fire suppression system.
When mixed correctly these parts form a homogeneous foam blanket that extinguishes flames by the combined mechanisms of cooling separating the flame source from the product surface suppressing vapors and smothering.
The main fire fighting agents in foam systems are known as aqueous film forming foams afff and if you choose the ansul system you have a variety of other foam agents to choose from.
Low expansion where the bubble expansion ratio is small less than 20 to 1 and the bubble contains a high water content.
The application technique and performance factors are the same for both the 3 and the 3 6 types of ar afff concentrates.
At these expansion ratios the bubble water.
Method of operation for foam water spray systems.
The size of the facility the hazard area to be protected the authority having jurisdiction and the assets being protected all play a big role in deciding what fire suppression system to use.
The intensity of the fire distance the foam must be thrown and the application rate also play an important part in determining the type of nozzle and method of extinguishment.
A combination of an automatic sprinkler system and a low level high expansion foam system.
Foam water systems generally work by allowing foam concentrate to mix with water flowing into the piping system.
Foam systems come in two types as follows.
For example in 2014 a civilian worker at eglin air force base died after being trapped in a foam filled hangar during an inadvertent system discharge.
Other components of fire retardant foams are.
They are mostly applicable to the protection of two dimensional flammable liquid hazards.
Firefighting foam is a foam used for fire suppression its role is to cool the fire and to coat the fuel preventing its contact with oxygen resulting in suppression of the combustion fire fighting foam was invented by the russian engineer and chemist aleksandr loran in 1902.
Foam water spray systems can be used for a combination of class a and class b hazards.